University of Leicester
Browse
Owen et al NMA of DTA J Clin Epi 2018.pdf (1.37 MB)

NETWORK META-ANALYSIS OF DIAGNOSTIC TEST ACCURACY STUDIES ALLOWING FOR MULTIPLE TESTS AT MULTIPLE THRESHOLDS FOR HEALTHCARE POLICY AND DECISION MAKING

Download (1.37 MB)
conference contribution
posted on 2019-04-17, 13:41 authored by R Owen, NJ Cooper, T Quinn, A Sutton
Objectives Network meta-analyses have extensively been used to compare the effectiveness of multiple interventions for healthcare policy and decision-making. Methods for evaluating the performance of multiple diagnostic tests are less established. In a decision-making context, we are often interested in comparing and ranking the performance of multiple diagnostic tests, at varying levels of test thresholds. The aim of this research was to develop a network meta-analysis framework for evaluating multiple diagnostic tests, at varying test thresholds in one simultaneous analysis. Methods Motivated by an example of cognitive impairment diagnosis following stroke, we synthesized data from 13 studies assessing the efficiency of two diagnostic tests: Mini-Mental State Examination (MMSE) and Montreal Cognitive Assessment (MoCA), at two test thresholds: MMSE <25/30 and <27/30, and MoCA <22/30 and <26/30. Using Markov Chain Monte Carlo (MCMC) methods, we fitted a bivariate network meta-analysis model, accounting for the correlations between multiple test accuracy measures from the same study, and incorporating constraints on increasing test thresholds assuming that higher test thresholds had an increased sensitivity but decreased specificity. Results We developed and successfully fitted a model comparing multiple tests/threshold combinations while imposing threshold constraints. Applying constraints on increasing test thresholds reduced the within-study variability and increased the precision in estimates of sensitivity and specificity. Using this model, we found that MoCA at threshold <26/30 appeared to have the best true positive rate (estimated sensitivity: 0.98; 95% credible interval (CrI): 0.94,0.99), whilst MMSE at threshold <25/30 appeared to have the best true negative rate (estimated specificity: 0.84, 95%CrI: 0.79,0.88). Conclusions In a health technology assessment setting, there is an increasing need to compare the efficiency of multiple diagnostics tests. The combined analysis of multiple tests at multiple thresholds allowed for more rigorous comparisons between competing diagnostics tests for decision-making.

Funding

The Complex Reviews Support Unit (CRSU) is funded by the National Institute for Health Research (project number 14/178/29).

History

Citation

Value in Health, 2018, 21, pp. S10-S10 (1)

Author affiliation

/Organisation/COLLEGE OF LIFE SCIENCES/School of Medicine/Department of Health Sciences

Version

  • AM (Accepted Manuscript)

Published in

Value in Health

Publisher

Elsevier for International Society for Pharmacoeconomics and Outcomes Research

issn

1098-3015

eissn

1524-4733

Copyright date

2018

Publisher version

https://www.sciencedirect.com/science/article/pii/S1098301518333576?via=ihub

Notes

The file associated with this record is under embargo until 12 months after publication, in accordance with the publisher's self-archiving policy. The full text may be available through the publisher links provided above.

Language

en

Usage metrics

    University of Leicester Publications

    Categories

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC